0.56" DIGITAL Red LED Frequency and Tachometer Rotate Speed Meter DC 12-24V

$ 7.01

Availability: 93 in stock
  • Return shipping will be paid by: Seller
  • Restocking Fee: No
  • All returns accepted: Returns Accepted
  • Refund will be given as: Money Back
  • Type: Tachometer
  • Country/Region of Manufacture: China
  • MPN: Does Not Apply
  • Brand: sktflyer
  • Features: Contact & Non-Contact Tachometer
  • Item must be returned within: 30 Days
  • Condition: New

    Description

    F
    eature:
    Power supply: DC/AC 12-24V
    Measure Range:
    Frequency
    : 0.1-99999Hz
    Rotate speed
    :30-99999 r/m
    Maxed Display:
    99999
    High
    frequency
    measurement accuracy
    , which could reach
    to
    0.01

    at 25 ° C
    ,
    resolution could reach to
    0.001HZ
    .
    Wide
    range
    of
    frequency   measurement
    :
    0.15HZ
    -
    100KHZ
    .
    Measuring range could be automatically switched
    from
    00.000Hz
    (
    R
    /   M
    )
    to
    000.00KHz
    (KR
    /
    M)
    .
    Work Modes:
    Frequency meter
    /
    Tachometer
    , you may change the
    mode via press the switch;
    Hold the work mode when power off
    Keys to set
    the
    divider
    value
    ,
    divided  by
    the value of
    1-99999
    and
    0.0001-9.9999
    file,
    the
    frequency
    value of
    power-down
    save
    Beautiful appearance
    , sophisticated technology
    and easy to use
    Specifications:
    Specifications
    Frequency meter
    Tachometer
    Display Digit
    0.56" 5-digits LED
    Display
    refresh ra
    te
    Signal frequency > 3HZ : 3 Times/ Sec
    Signal frequency ≤ 3HZ: about singnal frequency
    Over Flow Display
    “- - - - -”
    measurement accuracy
    0.1%±1digit / Special: 0.01‰ @ 25℃
    Measure Range
    0.15HZ—100KHZ
    9r-999.99Kr/m
    input signal
    Signal Type
    Dry contact、PNP、NPN、Pulse
    amplitude
    3-30V or 30-300V(High Voltage),this could be changed via adjust the
    Short circuit
    Measurement Method
    Full synchronization period measurement
    Input Resistance
    100KΩ
    Power Supply
    DC/AC 12-24V
    Withstand voltage
    AC2000V 1min Between the External terminal and the shell
    Anti-vibration
    Vibration Frequency :10-55HZ,  Acceleration: 50m/s2
    X、Y、Z, each direction 5min X 10
    Operating Temperature  and Humidity
    Temperature:-30℃-+70℃
    Humidity: 25-85% RH
    Storage Temperature
    -40℃-+80℃
    Panel Dimensions
    (mm)
    79X43X25(L×W×H)
    Cut-out Dimensions
    (mm )
    75X39.5
    Function Selection:
    Frequency and Rotate speed display Set
    (Please d
    isconnect the input signal
    before setting when the input signal is
    High level voltage signal)
    Open the back cover
    of the meter,
    Press
    "
    S2
    " key to enter "SET" model and then press "S1" to change display mode
    ,
    "0"
    means
    Frequency display
    with filter ;
    "1"
    means
    rotate speed
    with
    filter;
    "2
    "
    means
    Frequency display
    without filter ;
    "3"
    means
    rotate speed
    without
    filter.
    10 seconds
    later,
    this meter will
    automatically
    return
    to
    the
    measurement mode
    , or
    power-off
    and restart
    , this meter still could
    return to
    measurement mode too
    .
    Divider
    Value Set
    (
    Please d
    isconnect the input signal
    before setting when the input signal is
    High level voltage signal)
    Open the back cover
    , press the
    "
    S1
    " key
    to enter the
    Sub-
    frequency
    Value Set
    interface
    ,
    "
    S1
    "
    key   is
    the shift key
    ,
    "
    S2
    " key is the
    value
    plus
    key
    ,
    the
    divider
    value
    must be set
    in
    1-99999
    or
    0.0001-9.9999
    figures
    , and   other
    value
    is
    invalid
    ;After the
    set
    of
    the desired
    divider
    value via
    "
    S1
    " and
    "S2
    "
    ,
    wait   10 seconds
    and
    the meter will
    automatically
    return
    to
    the
    measurement
    mode
    ,
    or
    power-off
    and then restart
    to
    return
    to
    the
    measurement mode
    .
    Divider
    concept
    :
    The number of the singal the
    gears get for one circle
    .
    For example
    ,
    a
    gear
    can take
    20
    pulse signal
    for one circle ,
    the
    divider
    value
    could be
    set to
    20.
    High and Low voltage
    signal input
    switch
    (
    Please d
    isconnect the input signal
    before setting when the input signal is
    High level voltage signal)
    The
    default set for this meter is
    the
    low voltage input
    ,
    if you need
    high-voltage input
    ,
    you
    need
    to
    open  the back cover
    the more the short jumer from the "L
    "
    part.
    Enter
    the
    high voltage directly
    will
    damage
    the
    meter
    if the
    short jumper is not removed.
    We are not responsibility for this damage. Please
    carefully
    operation
    !!
    PIN Definition
    1:
    SIGNAL INPUT
    2: SINGNAL GND
    3: NC
    4:
    INPUT VOLTAGE "-" : GND
    5: INPUT VOLTAGE  "+" : VCC
    Singnal Type:
    Dry contact、PNP、NPN、Pulse
    Note:
    Please
    use the item
    in
    the
    normal
    environment
    Please
    select the correct operating mode
    for your application
    Please
    set
    the
    correct divider
    value
    Input signal
    should
    meet
    the
    requirements
    of
    impedance,
    if
    the
    internal impedance
    of
    the input
    signal
    is big and you need to change the impedance
    For
    safe operation
    , please do not
    set
    the meter if there is high lever input signal
    Please
    do not
    directly
    touch
    the
    crystal
    and chip
    directly due to body
    Static electricity can damage
    the
    device
    and reduce
    the
    performance
    .
    Package
    Frequency and
    Tachometer
    meter X 1pc